What could hurt a tenant, checked fireplace by fireplace
Plan a building visit
List the property, the fireplace count and the person who handles entry with tenants.
The safety items come first
In a rental, the chimney question is not about looks. It is whether anything in that fireplace can poison or burn someone who did not build it and may not know how it works. So each unit's visit opens with the same short list, before anything cosmetic.
State law calls for a CO alarm wherever a unit has gas appliances, a fireplace, or a garage attached to it. We note whether one is there and whether it responds to its test button. Keeping alarms in place is the owner's job; the findings give you the list to work from.
- A carbon monoxide alarm near the fireplace and the bedrooms, noted as present or missing
- The flue: cracked tile, gaps or blockages that could push smoke or gas into the room
- The damper: whether it opens fully and stays open
- Gas fireplaces and inserts: the vent connection, the cap and signs of spillage
- Soot, flakes or heat marks that point to an earlier chimney fire
- The hearth slab: cracks or gaps where a live coal could reach wood
After a fire in one unit
When a chimney fire hits one unit, the units that share the stack need a look too. Some older Los Angeles buildings run several flues through one masonry chimney, and heat from one can crack the tile walls beside it. We film the flue that burned and the flues next to it, and the findings say which units can use their fireplaces and which cannot.
Tenants need a straight answer. The findings for each unit end with one sentence on whether the fireplace is fit to use, which you can pass on exactly as written.
What lands in your file
One page per fireplace: unit number, what we checked, what we found, stills where there is something to show, and the verdict. A building summary on top lists every unit by status. Repairs go on a separate scope with the safety items at the top.
Entry is yours to arrange. We work from your schedule of units and leave each one as we found it.
Priced per fireplace
One line per fireplace on the invoice. A sixteen-unit building with eleven fireplaces pays for eleven.
- Tenant safety check, per fireplace
- $55
- Camera run of a flue, for units that need one
- $395
- Sweep for a unit that burns wood
- from $425
Gas vent and appliance repairs found during the visit go on the repair scope with their own figures.
Managers ask
Do units need a Level 2 every year?
No. For a fireplace with no change in use and no incident since the last visit, the per fireplace safety check is the usual yearly visit. A Level 2 makes sense after a fire, after a strong quake, when a unit switches from wood to gas, or when the safety check finds something it cannot judge.
What do you need from tenants?
Access to the fireplace and a clear hearth. Ask tenants to leave the fireplace unlit the day before, so the firebox is cold when we arrive.
A tenant reported a chimney fire. What first?
Make sure the fire department was called if anything is still burning. Then tell the tenant not to use the fireplace and book a camera visit for that flue and any flue in the same chimney. The findings come to you, and you decide what goes to the tenant.
Can the whole building be done in one visit?
Usually, if entry to each unit is lined up. Larger buildings may run over more than one visit, and the findings still arrive as one file.
Do you check the carbon monoxide alarms?
We note whether an alarm is present near each fireplace and whether it responds to its test button. Adding or replacing alarms is the owner's call; the findings list where they are missing.
Managing a building with fireplaces?
Send the property, the fireplace count and the entry contact through the contact page, and we return a visit plan and a per fireplace total.
Call (323) 524-3149